Determination of reference ranges for coagulation tests in Mexican-mestizo population
Keywords:
Reference Values, Blood Coagulation Tests, Prothrombin Time, Partial Thromboplastin Time, FibrinogenAbstract
Background: It is necessary to establish biological parameters for each population.
Objective: To establish reference values for prothrombin time (PT), activated partial thromboplastin time (PTT) and fibrinogen in healthy population and to determine intra- and inter-assay concordance.
Methods: Cross-sectional study that included 204 women and 202 men from the Blood Donor service. Coagulation tests were carried out in order to obtain reference ranges. All procedures were made according to the Clinical & Laboratory Standards Institute guidelines.
Results: Mean PT, PTT and fibrinogen were 14.1 s, 28.8 s and 381 mg/dL in men, and 15.1 s, 29.0 s and 381 mg/dL in women. The proposed PT, PTT and fibrinogen reference ranges for men were 12.7 to 16.3 s, 24.2 to 36.3 s and 239 to 276 mg/dL, respectively; for women, 12.7 to 16.6 s, 23.5 to 35.4 s and 276 to 598 mg/dL. The latter was statistically significant (p ≤ 0.001).
Conclusions: Reference values for blood coagulation tests were determined. This is of great importance for fast medical diagnosis and treatment. The results from this study can be adopted by other clinic laboratories after appropriate validation procedures.
Downloads
References
Solberg HE. International Federation of Clinical Chemistry (IFCC), Scientific Committee for Standardization in Haematology. Standing Committee on Reference Values. Approved recommendation (1986) on the theory of reference values. Part I. The concept of reference values. Clin Chem Acta. 1987;165:11-118.
Sánchez-Rodríguez MA. Valores de referencia o valores de corte clínicos: ¿Qué criterio tomar en el laboratorio clínico actual? Bioquimia. 2007;32(2):37-8. Disponible en http://www.redalyc.org/pdf/576/57632201.pdf
Sociedad Española de Química Clínica. Producción y utilización de valores de referencia. Química Clínica. 1987;6(1):49-68. Disponible en http://www.seqc.es/download/revista/664/1667/1054777793/1024/cms/Qumica%20Clnica%201987;6%20(1)%2049-68.pdf/
Clinical and Laboratory Standards Institute (CLSI). Defining, Establishing, and Verifying Reference Intervals in the Clinical Laboratory; Approved Guideline. Third edition. 2008;28:C28-A3.
Horowitz GL. Estimating Reference Intervals. Am J Clin Pathol. 2010 Feb;133(2):175-7.
Ceriotti F. Prerequisites for Use of Common Reference Intervals. Clin Biochem Rev. 2007 Aug;28(3):115-21.
Clinical and Laboratory Standards Institute (CLSI). Method Comparision and Bias Estimation Using Patient Samples; Approved Guidelina-Second Edition. EP9-A2, 22(19) Replaces EP9-A, 15.
Moreno-Hernández M, Luna-Gaspar AR, Magaña-Pérez JA, Ochoa-Rico A, Méndez-Tovar S, Ramírez-Pérez S, Reyes-Maldonado E et al. Consenso sobre estandarización de las pruebas de coagulación. Las recomendaciones nacionales del Grupo Cooperativo Mexicano de Hemostasia y Control de Calidad. Rev Hemostasia Tromb. 2008;2:102-14.
Cortina-de la Rosa E. Evaluación del fibrinógeno en la clínica. Revista Mexicana de Anestesiología. 2016;39 Suppl 2:S305-8.
10.NOM-007-SSA3-2011, Para la organización y funcionamiento de los Laboratorios Clínicos. México: Diario Oficial de la Federación; 27 de marzo de 2012. Disponible en http://dof.gob.mx/nota_detalle.php?codigo=5240925&fecha=27/03/2012
Escalante E, Escalante-Cragas EJ. Análisis y mejoramiento de la calidad. México: Limusa; 2006.
Mendoza Nuñez VM, Sánchez Rodríguez MA. Análisis y difusión de resultados científicos. 1ra. Ed. México: Facultad de Estudios Superiores Zaragoza, UNAM; 2001.
Lin Ll. A concordance correlation coefficient to evaluate reproducibility. Biometrics 1989;45(1):255-68.
NOM-253-SSA1-2012 Para la disposición de sangre humana con fines terapéuticos. México: Diario Oficial de la Federación: 26 de octubre de 2012. Disponible en https://www.gob.mx/cms/uploads/attachment/file/219069/NOM-253-SSA1-2012_Para_la_disposicion_de_sangre_humana_y_sus_componentes_con_fines_terapeuticos.pdf
Christensen RD, Baer VL, Lambert DK, Henry E, Ilstrup SJ, Bennett ST. Reference intervals for common coagulation test of preterm infants. Transfusion. 2014 Mar;54(3):627-32:quiz 626.
Jang JH, Seo JY, Bang SH, Park IA, Kim HJ, Kim SH. Establishment of reference intervals for von Willebrand factor antigen and eight coagulation factors in a Korean population following the Clinical and Laboratory Standards Institute guidelines. Blood Coagul Fibrinolysis. 2010 Apr;21(3):251-5.
Roshan TM, Rosline H, Ahmed SA, Rapiaah M, Wan Zaidah A, Khattak MN. Hematological reference values of healthy Malaysian population. Int J Lab Hematol. 2009 Oct;31(5):505-12.
Aral H, Usta M, Cilingirturk AM, Inal BB, Bilgi PT, Guvenen G. Verifying reference intervals for coagulation test by using stored data. Scand J Clin Lab Invest. 2011 Dec;71(8):647-52.
Calzada-Contreras A, Moreno-Hernández M, Castillo-Torres NP, Souto-Rosillo G, Hernández-Juárez J, Ricardo-Moreno MT et al. Valores de referencia para las pruebas de coagulación en México: utilidad de la mezcla de plasmas de donadores de sangre. Rev Invest Clin. 2012;64(5):437-43.
Díaz-Piedra P, Juárez-Bello HA, Lule Becerra FA. Determinación de los intervalos de referencia para las pruebas básicas de coagulación en población Mexicana. Rev Latinoam Patol Clin Med Lab. 2014;61(2):115-7.
Juárez-Pérez CA, Zempoalteca-Angulo YF, Haro-García LC, Mercado-García A, Jiménez-Ramírez C, Aguilar-Madrid G. Concordancia interlaboratorios en la cuantificación de plomo en la sangre. Rev Med Inst Mex Seguro Soc. 2014;52(1):28-33.
Molinero LM. Errores de medida en variables numéricas: Correlación y concordancia. Asociación de la Sociedad Española de Hipertensión. Agosto 2001. Disponible en https://www.alceingenieria.net/bioestadistica/concor1.pdf
Pita-Fernández S, Pértegas-Díaz S. La fiabilidad de las mediciones clínicas: el análisis de concordancia para variables numéricas. Unidad de Epidemiología y Bioestadística, Complejo Hospitalario Universitario de España, 2004. Disponible en http://www.fisterra.com/mbe/investiga/conc_numerica/conc_numerica.asp
Downloads
Published
Issue
Section
License
Authors retain their copyright and grant the Revista Médica del IMSS the right of first publication. Articles are distributed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which allows sharing as long as the author and the original source are properly credited.